S.M.A.R.T Warning (Speccy)

Atraxz

Prominent
Mar 13, 2017
1
0
510
I was wondering what's wrong with my drive. Says warning on speccy
Heres the list:
S.M.A.R.T
Status Warning
Temperature 36 °C
Temperature Range OK (less than 50 °C)
S.M.A.R.T attributes
Attribute name Real value Current Worst Threshold Raw Value Status
01 Read Error Rate 0 100 100 16 0000000000 Good
02 Throughput Performance 69 140 140 54 0000000045 Good
03 Spin-Up Time 19333414 ms 129 129 24 0001270126 Good
04 Start/Stop Count 1,238 100 100 0 00000004D6 Good
05 Reallocated Sectors Count 23 100 100 5 0000000017 Good
07 Seek Error Rate 0 100 100 67 0000000000 Good
08 Seek Time Performance 33 124 124 20 0000000021 Good
09 Power-On Hours (POH) 220d 23h 100 100 0 00000014B7 Good
0A Spin Retry Count 0 100 100 60 0000000000 Good
0C Device Power Cycle Count 1,232 100 100 0 00000004D0 Good
C0 Power-off Retract Count 1,322 99 99 0 000000052A Good
C1 Load/Unload Cycle Count 1,322 99 99 0 000000052A Good
C2 Temperature 35 °C 171 171 0 0000100023 Good
C4 Reallocation Event Count 34 100 100 0 0000000022 Good
C5 Current Pending Sector Count 0 100 100 0 0000000000 Good
C6 Uncorrectable Sector Count 0 100 100 0 0000000000 Good
C7 UltraDMA CRC Error Count 0 200 200 0 0000000000 Good
 
Solution
Do you have recent backups of your OS partition and your data partition? If not, begin making a full image backup of both partitions with Macrium Reflect or anything similar. After making restorable backups, download from the hard-drive manufacturer's web site the hard-drive diagnostics for your internal hard-drive -- and run the diagnositic's short and long tests.

RolandJS

Reputable
Mar 10, 2017
1,230
21
5,715
Do you have recent backups of your OS partition and your data partition? If not, begin making a full image backup of both partitions with Macrium Reflect or anything similar. After making restorable backups, download from the hard-drive manufacturer's web site the hard-drive diagnostics for your internal hard-drive -- and run the diagnositic's short and long tests.
 
Solution