In Win Classic Series C 900W PSU Review

Why you can trust Tom's Hardware Our expert reviewers spend hours testing and comparing products and services so you can choose the best for you. Find out more about how we test.

Transient Response Tests

Advanced Transient Response Tests

For details on our transient response testing, please click here.

Ιn these tests, we monitor the C900's response in two different scenarios. First, a transient load (10 A at +12V, 5 A at 5V, 5 A at 3.3V and 0.5 A at 5VSB) is applied for 200 ms while the PSU works at 20 percent load. In the second scenario, it's hit by the same transient load while operating at 50 percent load. In both tests, we use our oscilloscope to measure the voltage drops caused by the transient load. The voltages should remain within the ATX specification's regulation limits.

These tests are crucial because they simulate the transient loads a PSU is likely to handle (such as booting a RAID array or an instant 100 percent load of CPU/GPUs). We call these tests "Advanced Transient Response Tests," and they are designed to be very tough to master, especially for power supplies with a capacity of less than 500 W.  

Advanced Transient Response at 20 Percent

Swipe to scroll horizontally
VoltageBeforeAfterChangePass/Fail
12V12.278V12.080V1.61%Pass
5V5.080V4.982V1.93%Pass
3.3V3.330V3.205V3.75%Pass
5VSB4.976V4.945V0.62%Pass

Advanced Transient Response at 50 Percent

Swipe to scroll horizontally
VoltageBeforeAfterChangePass/Fail
12V12.168V12.068V0.82%Pass
5V5.030V4.937V1.85%Pass
3.3V3.292V3.161V3.98%Pass
5VSB4.928V4.883V0.91%Pass

Under light loads, the C900's resonant controller operates the primary switching FETs in PWM mode, so deviations during the first test are very high at +12V. The primary FETs operate in FM mode during the second test, so the transient loads are handled better. This is clearly shown by the <1% deviation on the same rail. The 5V and 5VSB rails fare pretty well, while the 3.3V rail is left behind with close to 4% deviations in both cases.

Here are the oscilloscope screenshots we took during Advanced Transient Response Testing:

Transient Response At 20 Percent Load

Transient Response At 50 Percent Load

Turn-On Transient Tests

In the next set of tests, we measure the PSU's response in simpler transient load scenarios—during its power-on phase.

For the first measurement, we turn off the PSU, dial in the 5VSB rail's maximum current, and switch the C900 back on. In the second test, we dial the maximum load the +12V can handle and start the PSU while it's in standby mode. In the last test, while the C900 is completely switched off (we cut the power or switch the power supply off by flipping its switch), we dial the +12V rail's maximum load before switching the PSU on from the loader and restoring power. The ATX specification states that recorded spikes on all rails should not exceed 10 percent of their nominal values (+10 percent for 12 V is 13.2 V, and 5.5 V for 5 V).    

There is a small voltage overshoot at 5VSB that's much lower than the limit, so there is nothing to worry about. We also see a small spike at +12V during the last test, which is also insignificant.

Contributing Editor

Aris Mpitziopoulos is a Contributing Editor at Tom's Hardware US, covering PSUs.

  • Dark Lord of Tech
    Does the EVGA P2 series have OTP?
    Reply
  • Aris_Mp
    newer batches have according to my sources. Older ones didn't have.
    Reply
  • Johan Kryger Haglert
    Terrible bang for the buck you mean.
    Reply
  • Dark Lord of Tech
    18741010 said:
    newer batches have according to my sources. Older ones didn't have.

    Thank you much appreciated!!!!
    Reply
  • falchard
    It's not a terrible buy. If you have a beautiful in-Win case, can you really tell yourself the best PSU for the price should be placed in there?
    Reply