Protection Features
Check out our PSUs 101 article to learn more about PSU protection features. Our protection features evaluation methodology is described in detail here.
Protection Features | |
---|---|
OCP | 12V: 142A (113.6%) - 11.99V 5V: 34A (155%) 3.3V: 37.3A (149%) 5VSB: 5.1A (170%) |
OPP | 1702.6W (113.51%) |
OTP | ✓ (160°C ambient @ secondary side) |
SCP | 12V: ✓ 5V: ✓ 3.3V: ✓ 5VSB: ✓ -12V: ✓ |
PWR_OK | Does not function correctly |
NLO | ✓ |
SIP | Surge: MOV Inrush: NTC thermistor & bypass relay |
The OCP levels on every rail except for +12V are at their usual high levels. On the other hand, over-power protection is configured on the low side, mostly because of this PSU's already-monstrous capacity. Over-temperature protection is supported, and again, we noticed that the power-good signal is inaccurate (it drops after the rails go out of spec).
MORE: Best Power Supplies
MORE: How We Test Power Supplies