Skip to main content

BenQ SW271 27-Inch Monitor Review: Nearly Perfect

Editor's Choice

OSD Setup & Calibration

The SW271 works well in its preset color modes but also offers one of the most precise set of calibration controls we’ve seen to date. Nearly any combination of gamut, white point and gamma is possible. The OSD sticks to BenQ’s familiar tree-style design and is simple to operate.

Image 1 of 14

Image 2 of 14

Image 3 of 14

Image 4 of 14

Image 5 of 14

Image 6 of 14

Image 7 of 14

Image 8 of 14

Image 9 of 14

Image 10 of 14

Image 11 of 14

Image 12 of 14

Image 13 of 14

Image 14 of 14

Pressing any control key on the panel or the puck brings up a quick menu. The first three slots can be programmed for different functions and you can press the fourth button for the full OSD.

The Display menu has an input selector and three aspect-ratio options. Full stretches the image to fit the screen if it’s not already 3840 x 2160 pixels. Aspect uses as much screen as possible without changing the picture’s shape. And 1:1 keeps lower-res images at their native size, which means they’re shown in a window.

All the calibration options live in the Color Adjustment menu. It starts off with eight preset picture modes, which lock out most other adjustments. You can change brightness in all of them and color temp in some, but a full calibration is only possible in the two Custom memories. If you use the Palette Master Element software, you’ll get three additional slots for that purpose. The HDR preset emulates HDR with SDR material. The SW271 supports true HDR10 signals and switches to that mode when appropriate. While calibration isn’t possible there, calibration isn’t actually needed, as you’ll see in our tests on page five.

To adjust color temperature, choose one of the presets, change it with a Kelvin slider in 100K increments, or tweak the RGB controls (they’re extremely precise, as you’ll see in our benchmark result). Gamma options range from 1.6 to 2.6 in .2 increments and are also right on the money. If you set 2.2, you get 2.2. And that’s true in every color mode.

The Custom memories also allow one to choose a color gamut, which we wish every pro monitor allowed. Too many products lock you out of certain adjustments in different gamut modes. The SW271 lets you choose any combination of gamut, white point and gamma you wish, and each gamut allows adjustment to hue and saturation values. Once you’ve completed an OSD calibration, choose Save Color Settings to lock in all changes. You can also reset everything if you get too far afield.

The PIP/PBP feature goes beyond displaying two sources simultaneously. You can also adjust the color gamut, white point, gamma and brightness for each. You’ll need two computers for this trick, but it allows you to compare the effects of these settings on a single image. We’ve never seen PBP used this way on any other monitor.

The System menu has OSD language choices, a calibration reminder and signal luminance range options and features for DisplayPort and USB-C ports. Custom Keys refer to the first three bezel buttons, while Controller Key lets you change the function of the three buttons on the Hotkey Puck. You can set the Hotkey Puck buttons to allow quick access to things like color mode, PIP/PBP, gamma and others. Because of its total of six programmable buttons, you’ll rarely need to navigate the OSD to change settings.

Calibration

The SW271 comes out of the box in its Adobe RGB mode. While its gamma and gamut targets are spot-on, the white point on our sample needed a little touch-up. We found the same behavior in the DCI-P3 and sRGB modes.

We decided to create two custom calibrations, one for DCI and one for sRGB. We chose 2.2 gamma for the latter, 2.4 for the former and a D65 white point for both. After a few clicks of the RGB sliders, we achieved reference-level accuracy. If you prefer a software solution, you can download BenQ’s Palette Master Element software. It supports most popular meters, including X-rite’s i1 Pro and i1 DisplayPro. You can save its automatic adjustment to one of three memories.

We’ve provided our OSD settings below for the two Custom modes. Stated Brightness values will provide the same output levels regardless of mode or other settings.

BenQ SW271 Calibration Settings
Brightness 200 nits59
Brightness 120 nits30
Brightness 100 nits24
Brightness 80 nits17
Brightness 50 nits7
Custom 1 (DCI-P3) ModeGamma 2.4Red 99, Green 98, Blue 100
Custom 2 (sRGB) ModeGamma 2.2Red 100, Green 98, Blue 100

MORE: Best Gaming Monitors