Transient Response Tests

Advanced Transient Response Tests

For details on our transient response testing, please click here.

Ιn these tests, we monitor the EA-750G's response in several scenarios. First, a transient load (10A at +12V, 5A at 5V, 5A at 3.3V, and 0.5A at 5VSB) is applied for 200ms as the PSU works at 20 percent load. In the second scenario, it's hit by the same transient load while operating at 50 percent load.

In the next sets of tests, we increase the transient load on the major rails with a new configuration: 15A at +12V, 6A at 5V, 6A at 3.3V, and 0.5A at 5VSB. We also increase the load-changing repetition rate from 5 Hz (200ms) to 50 Hz (20ms). Again, this runs with the PSU operating at 20 and 50 percent load.

The last tests are even tougher. Although we keep the same loads, the load-changing repetition rate rises to 1 kHz (1ms).

In all of the tests, we use an oscilloscope to measure the voltage drops caused by the transient load. The voltages should remain within the ATX specification's regulation limits.

These tests are crucial because they simulate the transient loads a PSU is likely to handle (such as booting a RAID array or an instant 100 percent load of CPU/GPUs). We call these "Advanced Transient Response Tests," and they are designed to be very tough to master, especially for a PSU with a capacity of less than 500W.  

Advanced Transient Response at 20 Percent – 200ms

Swipe to scroll horizontally
VoltageBeforeAfterChangePass/Fail
12V12.066V11.911V1.28%Pass
5V5.038V4.913V2.48%Pass
3.3V3.312V3.197V3.47%Pass
5VSB5.073V5.018V1.08%Pass

Advanced Transient Response at 20 Percent – 20ms

Swipe to scroll horizontally
VoltageBeforeAfterChangePass/Fail
12V12.066V11.841V1.86%Pass
5V5.038V4.895V2.84%Pass
3.3V3.313V3.182V3.95%Pass
5VSB5.073V5.028V0.89%Pass

Advanced Transient Response at 20 Percent – 1ms

Swipe to scroll horizontally
VoltageBeforeAfterChangePass/Fail
12V12.067V11.846V1.83%Pass
5V5.038V4.905V2.64%Pass
3.3V3.312V3.181V3.96%Pass
5VSB5.073V5.017V1.10%Pass

Advanced Transient Response at 50 Percent – 200ms

Swipe to scroll horizontally
VoltageBeforeAfterChangePass/Fail
12V12.066V11.911V1.28%Pass
5V5.038V4.913V2.48%Pass
3.3V3.312V3.197V3.47%Pass
5VSB5.073V5.018V1.08%Pass

Advanced Transient Response at 50 Percent – 20ms

Swipe to scroll horizontally
VoltageBeforeAfterChangePass/Fail
12V12.061V11.846V1.78%Pass
5V5.030V4.885V2.88%Pass
3.3V3.298V3.152V4.43%Pass
5VSB5.045V5.003V0.83%Pass

Advanced Transient Response at 50 Percent – 1ms

Swipe to scroll horizontally
VoltageBeforeAfterChangePass/Fail
12V12.062V11.858V1.69%Pass
5V5.030V4.878V3.02%Pass
3.3V3.297V3.163V4.06%Pass
5VSB5.045V4.972V1.45%Pass

The response on every rail except 5VSB isn't particularly great. We expected lower voltage drops at +12V, while the 3.3V rail falls below 3.2V in every test.

Here are the oscilloscope screenshots we took during Advanced Transient Response Testing:

Transient Response At 20 Percent Load – 200ms

Transient Response At 20 Percent Load – 20ms

Transient Response At 20 Percent Load – 1ms

Transient Response At 50 Percent Load – 200ms

Transient Response At 50 Percent Load – 20ms

Transient Response At 50 Percent Load – 1ms

Turn-On Transient Tests

In the next set of tests, we measured the EA750G Pro's response in simpler transient load scenarios—during its power-on phase.

For our first measurement, we turned the EA750G Pro off, dialed in the maximum current the 5VSB rail could output, and switched the PSU back on. In the second test, we dialed the maximum load the +12V rail could handle and started the 750W supply while it was in standby mode. In the last test, while the PSU was completely switched off (we cut off the power or switched the PSU off), we dialed the maximum load the +12V rail could handle before switching it back on from the loader and restoring power. The ATX specification states that recorded spikes on all rails should not exceed 10 percent of their nominal values (+10 percent for 12V is 13.2V, and 5.5 V for 5V).

There is a tiny spike at 5VSB. In the other two tests, the +12V rail needs some time to settle down to its nominal voltage. All in all, we observe decent performance, though the results are not perfect.


MORE: Best Power Supplies